If you are searching for specific sections within the PDF, look for these chapters:
Note on "904" vs "90.4": If you were actually looking for ASHRAE Standard 4 (Methods of Testing for Rating), that is a different document. However, based on your request for "PDF," Standard 90.4 (Data Centers) is the most commonly requested download.
The ANSI/ASHRAE Standard 90.4, established by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, serves as the primary energy efficiency standard for data center design and operation. As of early 2026, the standard is transitioning from the widely adopted 2022 edition to the newly released 2025 edition, which expands its focus from pure energy efficiency to broader sustainability goals. Core Purpose and Scope
Standard 90.4 provides a performance-based framework tailored to the mission-critical nature of data centers. Unlike its sister standard, ASHRAE 90.1, which covers general building energy, 90.4 specifically addresses the high-density cooling and power needs of IT environments.
Application: Applies to facilities with IT equipment loads greater than 10 kW and power densities over 20 W/ft².
Compliance Pathways: Designers must meet thresholds for two critical components:
Mechanical Load Component (MLC): Evaluates the efficiency of cooling systems, including fans, pumps, and heat rejection equipment. ashrae 904 pdf upd
Electrical Loss Component (ELC): Measures the worst-case losses across the power chain, including UPS and distribution systems. Key Updates in the 2025 Edition
The ASHRAE 90.4-2025 version marks a significant evolution in the standard’s mission:
Expanded Sustainability Goals: The purpose now includes monitoring greenhouse gas (GHG) emissions, water consumption, and overall environmental impact alongside energy use.
Decarbonization Focus: New language supports future inclusion of broader decarbonization and resource impact considerations.
Refined Definitions: Updates to process heat and ventilation definitions support stricter regulation of these components in modern facilities.
UPS Calculations: Clarifies that UPS efficiency must be calculated based on total available capacity, including redundant components, to accurately reflect real-world operational losses. Legacy Requirements from the 2022 Edition If you are searching for specific sections within
Most current projects still adhere to the 2022 requirements, which introduced several critical shifts: ASHRAE 90.4 created to boost data center energy efficiency
Recognizing that 2N or N+1 cooling architectures inherently consume more energy, the 2022 edition allows a PUE multiplier for facilities with full redundancy. For example:
This change prevents penalizing high-availability designs while still driving efficiency improvements.
Mechanical Load Component (MLC) & Electrical Loss Component (ELC)
Expansion to Telco Facilities
Compliance Paths
PUE (Power Usage Effectiveness) Trap
Manufacturers and designers now have a simplified path for air-cooled chillers serving data centers: compliance with 90.4 automatically if the chiller meets 90.1’s integrated part-load value (IPLV) requirements and the facility’s cooling system uses variable-speed drives on all fans and pumps.
Using an outdated ASHRAE 90.4 (e.g., 2016 or 2019 PDF) can lead to:
Compliance is achieved by demonstrating that the facility’s design PUE is less than or equal to the allowable PUE from the standard’s tables. The design PUE is calculated as:
PUE_design = (IT Load + Cooling Load + Power Distribution Losses + Lighting + Ancillary Loads) / IT Load
Where: