Eliwell Sb655 C Manual

| Parameter | Value | |-----------|-------| | Power Supply | 230Vac ±10%, 50/60Hz | | Power Consumption | 3 VA max | | Operating Temperature | 0 to 55°C (32 to 131°F) | | Storage Temperature | -20 to 70°C (-4 to 158°F) | | Relative Humidity | 10-90% non-condensing | | Probe Input | PTC (1000Ω @ 25°C) or NTC (103AT-2) | | Measurement Range | -50 to +110°C (-58 to 230°F) | | Resolution | 0.1°C (1°F) | | Outputs: Compressor | SPST relay, 16A resistive @ 250Vac | | Outputs: Defrost | SPST relay, 8A resistive @ 250Vac | | Digital Input | Volt-free contact | | Protection Class | IP65 front panel | | Mounting | Panel (71x29mm cutout) |


| Model | Description | |-------|-------------| | SB655C | 230Vac, PTC/NTC, 2 relays | | SB655C 12V | 12Vac/dc version | | NP010 | NTC probe (103AT-2, 3m cable) | | PP010 | PTC probe (3m cable) | | FPL200 | Panel gasket for IP65 |


Overall Verdict:
A functional but dense technical manual. It contains all necessary information for installation, programming, and troubleshooting—but lacks clear organization or real-world examples, making it challenging for first-time users. eliwell sb655 c manual


| Symptom | Possible Cause | Solution | |---------|----------------|----------| | Compressor does not start | Anti-short cycle (AC) active | Wait. Reduce AC if needed. | | | Setpoint > room temp | Lower setpoint. | | | Probe defective | Replace probe. | | Continuous defrost | dE set too high, or dS too low | Reduce dE, increase dS. | | Display shows OFF | Unit in standby | Press ON/OFF for 3s. | | Erratic temperature | Wrong probe type (P2) | Set P2 to match probe. |


If the SB655 C is beeping or flashing, here is what the manual says: | Parameter | Value | |-----------|-------| | Power

| Error Code | Meaning | Solution | | :--- | :--- | :--- | | P1 | Probe 1 (Ambient) shorted or open circuit. | Check wiring on terminals 1 & 2. Replace probe (10k NTC). | | P2 | Probe 2 (Evaporator) fault. | Check wiring on terminals 3 & 4. Jumper between 1 & 4 present? | | HA | High temperature alarm (exceeded AL2). | Check if door is open, condenser is dirty, or gas is low. | | LA | Low temperature alarm (below AL1). | Check if setpoint is too low or if probe is unplugged in warm air. | | EE | Internal memory failure. | Controller is faulty. Replace SB655 C unit. | | cEF | Defrost timeout – evaporator did not end defrost. | Defrost duration (c5) too short, or heater is burnt out. | | dor | Door open alarm (if digital input enabled). | Close the door or check door switch terminals 5-7. |

The manual includes:

Missing: