Press ESC to close

Do not dispose of in household waste. The ES99 contains a non‑user‑serviceable lithium battery. Return to an electronic recycling center or to MicroNova via their take‑back program.


Document revision history


This manual is verified against production unit ES99 serial prefix MN-ES99-2025A and later.

The Micronova ES99 (Atlas Copco part #2202842000) is a control module primarily used for energy management in rotary screw air compressors, such as those from Atlas Copco, Chicago Pneumatic, and Ceccato. Technical Specifications Power Supply: 12 VAC, 50/60 Hz, 250 mA.

Physical Dimensions: Approximately 250 mm x 155 mm x 130 mm (LxWxH).

Interface: Features an LCD display for real-time monitoring of pressure, temperature, and service alerts.

Application: Designed to monitor, control, and protect compressor systems via automatic start/stop and safety shutdowns. Operational Indicators and Warnings

The ES99 provides visual feedback through an LCD or LED interface to signal system status or malfunctions:

Safety Protections: It monitors for motor thermal protection, power supply phase errors, and compressor overheating.

Remote Control: Features a dedicated dip switch setting to activate or deactivate remote operation.

Auto-Restart: Can be configured via dip switches to automatically restart the system after a power interruption. Wiring and Connectivity (Pinout CN1)

Standard configurations for the ES99 (often shared with the ES3000 series) include the following terminal connections: Overload Motor: Pins 4 – 3 (Normally closed).

Rotation Direction: Pins 5 – 3 (Normally closed; signals wrong rotation).

Oil Temperature: Pins 6 – 3 (Normally closed; signals over temperature).

Pressure Switch: Pin 10 – 3 (Open if P > Pmax; Closed if P < Pmin). Emergency Push Button: Pin 12 – 3 (Normally closed). Maintenance and Verification ES99 Control by MICRONOVA - Radwell International

Micronova ES99 is a specialized control module primarily used in industrial equipment, most notably as a controller for Atlas Copco air compressors

. Verified user manuals and technical documentation for this device typically cover its installation, wiring, and operational parameters for energy-saving industrial applications. Radwell International Overview of the Micronova ES99 Controller

The ES99 functions as an energy-saving control module designed to manage industrial machinery. According to its specifications, it typically operates at

with a frequency of 50/60 Hz. Although discontinued by some manufacturers, it remains a critical component in many legacy air compressor systems, such as the Atlas Copco 2202842000. Radwell International Key Technical Specifications Voltage Requirement Power Consumption Primary Application : Control and monitoring of air compressors. Manufacturer : Micronova (Italy). Radwell International Verified Manuals and Resources

To properly configure or troubleshoot the device, you should refer to these verified technical documents: Instruction Manuals

: Comprehensive guides for the ES99 are available on document-sharing platforms like Scribd (Es99 Manual) Wiring Diagrams

: For integration into compressor systems, detailed wiring diagrams are often included in broader Atlas Copco service manuals. Replacement & Support : Since the part is discontinued, retailers like Radwell International

provide technical data and warranty-backed replacements for the module. Radwell International Common Troubleshooting Steps Power Supply Check

: Verify that the incoming voltage is a stable 12 VAC. Fluctuations can cause the controller to reset or fail. Wiring Inspection

: Ensure all terminal connections match the specific wiring diagram for your compressor model. Sensor Validation

: The ES99 relies on pressure and temperature sensors; ensure these are functioning correctly to avoid false error codes. or a specific troubleshooting guide for a particular compressor model? Es99 Controller | PDF - Scribd

If you have lost the physical booklet, do not panic. Here is the step-by-step path to obtaining the micronova es99 user manual verified file:

Return / RMA – obtain RMA number before shipping; original packaging required.


| Parameter | Value | |-----------|-------| | Temperature accuracy | ±0.3°C (0–50°C) | | Humidity accuracy | ±3% RH (20–80% RH) | | eCO₂ range | 400 – 5000 ppm | | VOC range | 0 – 60,000 ppb (TVOC) | | Pressure accuracy | ±1 hPa | | Noise range | 30 – 100 dBA (±1.5 dBA) | | Light range | 0 – 65,535 lux | | Wireless | BLE 5.2 (10 m range), LoRaWAN (2 km line‑of‑sight) | | Power | 5V DC / 0.5A typical, 1A peak | | Dimensions | 82 × 82 × 24 mm | | Weight | 95 g |


| Symptom | Likely cause | Solution | |---------|--------------|----------| | No LED | No power | Check USB cable / adapter; try another port. | | LED solid red | Sensor failure | Factory reset; if persists, contact support. | | eCO₂ stuck at 400 ppm | No self‑calibration run | Manual zeroing (section 8.2). | | Bluetooth not found | Device already paired elsewhere | Reset Bluetooth: hold pairing button 10 s. | | High VOC reading always | Nearby source (printer, paint) | Relocate device >1 m away. |