Fix | Wincc Viewer Rt Download

The "WinCC Viewer RT" download and installation issues are predominantly caused by source file corruption and environment incompatibilities rather than a software bug. By adhering to official Siemens channels for download and following the strict pre-requisite checklist (OS Version and .NET Framework), a successful installation can be guaranteed.

Status: Issue Resolved. Procedure updated in internal knowledge base.

If the viewer fails to connect or freezes, it is often due to a corrupted or incorrect configuration file (WinCCViewerRT.xml).

The Fix: Delete or rename the existing XML file to force a re-configuration. Standard File Locations:

Windows 7/10/Server 2008+: C:\Users\\AppData\LocalLow\Siemens\SIMATIC.WinCC\WebNavigator\Client\WinCCViewerRT.xml.

Older Systems: C:\Documents and Settings\\Application Data\Siemens\SIMATIC.WinCC\WebNavigator\Client\WinCCViewerRT.xml.

Action: After deleting the file, restart WinCCViewerRT.exe. This will trigger the configuration dialog where you can re-enter the server IP and user credentials. 2. Run with Elevated Permissions

Some users report that the viewer only works when executed with administrative rights.

The Fix: Right-click on WinCCViewerRT.exe (found in ... \WebNavigator\Client\bin) and select Run as Administrator.

Persistence: To make this permanent, right-click the file > Properties > Compatibility tab > check Run this program as an administrator. 3. Repair the WebNavigator Client Installation

If the application refuses to start or files appear missing, the installation itself may be compromised. The Fix:

Open the Windows Control Panel and navigate to Programs and Features. Select the WinCC/WebNavigator Client. Choose Change/Uninstall and select the Repair option.

Restart the PC after the process completes to ensure all system files and group policies are applied. 4. Verify Network and Windows Features wincc viewer rt download fix

For newer WinCC versions (like Unified), ensure your OS is prepared to handle the runtime environment.

Windows Features: Ensure ASP.NET 4.5 (or higher) and Internet Information Services (IIS) are enabled in "Turn Windows features on or off".

Firewall: Ensure the WebNavigator port (default 80 for HTTP or 443 for HTTPS) is not blocked by a local or corporate firewall. Quick Tips for Configuration WinCCViewer RT - SiePortal - Siemens

Troubleshooting a failing download to WinCC Viewer RT can be a headache, especially when your remote SCADA monitoring depends on it. Whether you're seeing a "Failed to create empty document" error or the system simply won't connect, this guide will walk you through the most effective fixes. Fixing WinCC Viewer RT Connection & Download Failures

When WinCC Viewer RT stops working, the issue is often tied to corrupted configuration files, user permissions, or network settings. Use the following steps to resolve these common bottlenecks. 1. Clear the Configuration Cache

One of the most frequent causes of a failed startup is a corrupted .xml configuration file. Deleting this file forces the viewer to regenerate a clean configuration upon its next launch.

Locate the file: Navigate to the following path on the client PC:C:\Users\\AppData\LocalLow\Siemens\SIMATIC.WinCC\WebNavigator\Client\

Action: Find the file named WinCCViewerRT.xml and delete or rename it.

Result: Restart the application; it will prompt you for fresh server details, potentially clearing any "Failed to create empty document" errors. 2. Run as Administrator

If the viewer only works for some users or failed to download the initial WebNavigator plugins, try launching it with elevated privileges.

Right-click WinCCViewerRT.exe in your installation directory (typically ...\SIEMENS\WINCC\WebNavigator\Client\bin).

Select Run as administrator. If this fixes the issue, consider adjusting the user's permanent Windows profile permissions or recreating the profile if the problem persists for specific users. 3. Verify Simatic Shell & Remote Connections The "WinCC Viewer RT" download and installation issues

If you are trying to access SCADA from a remote PC or via VPN, the "Allow remote connection" setting is a common culprit.

On the Server PC, open Simatic Shell (usually found in Windows Explorer under "This PC" or the "Desktop"). Right-click on Simatic Shell and select Settings.

Ensure "Allow remote connection" is checked and the correct network card (IP address) is selected for communication. 4. Manual File Transfer (Workaround)

If the engineering station is failing to download the runtime project to the HMI or target PC, you can bypass the downloader entirely.

Compile the project on your engineering station to generate the .pdata or .fwc files.

Copy the project folder to a removable drive or network share.

Manually paste the files into the target path configured in the WinCC Runtime Loader on the destination machine. 5. Check SVG & Graphics Compatibility

In newer versions like WinCC Professional V18, certain graphical elements (like SVGs) might disappear in the Viewer RT if "Classic Mode" is active.

Disable Classic Mode in your runtime settings if SVG symbols are failing to display.

Ensure all screens are marked as Web-enabled in the WinCC Explorer properties before publishing. Still stuck? WinCCViewer RT - SiePortal - Siemens

WinCCViewerRT is a specialized tool used to access HMI runtime projects remotely via a WebNavigator server. A standout "feature" often used as a fix for configuration and connection issues is the hidden property menu shortcut Siemens SiePortal Key Feature: The "Ctrl + Alt + P" Configuration Fix

One of the most useful features of the WinCC Viewer RT is the ability to call up the project configuration window even after the viewer has already been set up. Siemens SiePortal How it works : While the WinCCViewerRT.exe application is running, pressing Ctrl + Alt + P on your keyboard triggers the properties window. Why it's a "fix" Server Reconnection This report details the investigation and resolution of

: If you lose connection or need to point the viewer to a new server IP or web address, you can quickly update the connection string without digging through XML files. Resolution Adjustments

: It allows you to fix display issues where the screen might be cut off or scaled incorrectly by adjusting the runtime properties on the fly. User Profiles : It is a faster alternative to manually deleting the WinCCViewerRT.xml file located in the user's folder to reset the application. Siemens SiePortal Common Fixes for Viewer Issues

Beyond the shortcut, here are some standard "fixes" for common WinCC Viewer RT errors: "Failed to create empty document"

: This often points to a corrupted user profile or missing Windows components like SIMATIC NET Black Background/Missing Symbols

: If SVG symbols disappear or the screen turns black, try toggling the Enable Runtime Viewer

setting in the WinCC Explorer computer properties to regenerate the license key file. Application Hanging

: Surprisingly, some users have fixed viewer "freezes" by simply changing or reconnecting their default Windows printer

, as the viewer sometimes hangs while trying to poll network printer status. Siemens SiePortal

For official troubleshooting steps and software downloads, you can refer to the Siemens Industry Online Support (SIOS) SiePortal Forum Are you experiencing a specific error message like "No connection to server," or are you looking for a direct download link for a specific version?

WinCC 7.5 Web Navigator "No connecting to server" error - SiePortal

Installing SIMATIC NET V16 solved the problem, both WinCC Viewer RT and IE web client connexions work now. Siemens SiePortal Web Navigator problem - SiePortal

I understand you're looking for guidance on WinCC (Siemens) Runtime Viewer download and fixing common issues. Here’s a structured, practical guide.


This report details the investigation and resolution of issues encountered during the download and installation of the WinCC Runtime Viewer (WinCC Viewer RT). Users reported failed downloads, incomplete installations, and runtime errors upon launch. The primary causes were identified as corrupted download sources, prerequisite software incompatibilities, and strict Windows User Account Control (UAC) settings. The solutions outlined below provide a stable path for successful deployment.

Open Simatic Security Settings on both machines: